Structural performance optimization of Reinforced concrete buildings with rooftop Telecommunication towers: A location-based analysis

dc.contributor.authorOjha, Bimal
dc.contributor.authorKhatri, Sabin
dc.contributor.authorPokharel, Prabin
dc.contributor.authorJirel, Rasique
dc.contributor.authorJamarkattel, Binay
dc.contributor.authorKhatri, Abhinesh
dc.date.accessioned2026-09-22T11:31:54Z
dc.date.issued2024-12-30
dc.descriptionJournal: Journal of Innovations in Engineering Education (JIEE), ISSN 2594-343X (print), 2773-823X (online) Volume/Issue: Vol. 7, Issue 1 (2024), pages 131-137 Article type: Research Article Published: 2024-12-30 DOI: https://doi.org/10.3126/jiee.v7i1.72513 Authors and affiliations: - Bimal Ojha (Department of Civil Engineering, Institute of Engineering, Thapathali Campus) - Sabin Khatri (Department of Civil Engineering, Institute of Engineering, Thapathali Campus) - Prabin Pokharel (Department of Civil Engineering, Institute of Engineering, Thapathali Campus) - Rasique Jirel (Department of Civil Engineering, Institute of Engineering, Thapathali Campus) - Binay Jamarkattel (Department of Civil Engineering, Institute of Engineering, Thapathali Campus) - Abhinesh Khatri (Department of Civil Engineering, Kantipur Engineering College) TCIOE department(s): Department of Civil Engineering Publisher: Thapathali Campus, Institute of Engineering, Tribhuvan University License: Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0), https://creativecommons.org/licenses/by-nc-nd/4.0/ Journal website: https://journal.tcioe.edu.np/articles/aa0efe81-c70f-4b53-a1ee-a37d867684bd NepJOL: https://www.nepjol.info/index.php/jiee/article/view/72513
dc.description.abstractThis study evaluates the structural response of an RCC building in Parbat, Nepal, with a rooftop telecommunication tower positioned at various locations. In our case, a telecommunication tower is already located at a certain position in the building, and we are trying to evaluate the optimal position of telecommunication tower. The site lies in seismic Zone V as per IS 1893:2016 (Part 1), indicating very high seismic activity, and is subject to significant wind loads. This study examines the structural response of an RCC building with a rooftop telecommunication tower, using ETABS 18.1.1 and adhering to IS 1893:2016 (Part 1) seismic design standards. The analysis focuses on the impact of tower placement on critical structuralparameters, such as base shear, nodal displacement, axial and shear forces, and bending and torsional moments. Through five tower placement scenarios, the study highlights significant findings: a 2.37% increase in base shear, up to 9.86% variation in axial forces, and a maximum 26.60% change in shear forces. By isolating tower location as a variable, this research provides detailed insights into how tower positioning affects building performance. A finite element analysis approach is used, ensuring accuracy by explicitly modeling RCC-steel tower interactions and bolted connection of telecommunication tower and RCC structure.
dc.format.extentpp. 131-137
dc.identifier.citationOjha, B., Khatri, S., Pokharel, P., Jirel, R., Jamarkattel, B., & Khatri, A. (2024). Structural performance optimization of Reinforced concrete buildings with rooftop Telecommunication towers: A location-based analysis. Journal of Innovations in Engineering Education, 7(1), 131-137. https://doi.org/10.3126/jiee.v7i1.72513
dc.identifier.doi10.3126/jiee.v7i1.72513
dc.identifier.issn2594-343X
dc.identifier.issn2773-823X
dc.identifier.urihttps://elibrary.tcioe.edu.np/handle/123456789/306
dc.language.isoen
dc.publisherThapathali Campus, Institute of Engineering, Tribhuvan University
dc.relation.ispartofseriesJournal of Innovations in Engineering Education;Vol. 7, Issue 1 (2024)
dc.relation.urihttps://doi.org/10.3126/jiee.v7i1.72513
dc.relation.urihttps://www.nepjol.info/index.php/jiee/article/view/72513
dc.relation.urihttps://journal.tcioe.edu.np/articles/aa0efe81-c70f-4b53-a1ee-a37d867684bd
dc.rightsCopyright (c) 2024 JIEE and the authors. Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0).
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceJournal of Innovations in Engineering Education, Vol. 7, Issue 1 (2024), pp. 131-137
dc.subjectTelecommunicationtowerplacement Structural optimization
dc.subjectETABS
dc.subjectFinite Element Analysis
dc.subjectSeismic performance
dc.subjectRCC building response
dc.subjectTower-Structure interaction
dc.subjectJIEE
dc.subjectJournal of Innovations in Engineering Education
dc.subjectJIEE 2024
dc.subjectJIEE Volume 7
dc.subjectResearch Article
dc.subjectThapathali Campus
dc.subjectTCIOE
dc.subjectInstitute of Engineering
dc.subjectIOE
dc.subjectTribhuvan University
dc.subjectNepal
dc.subjectengineering research Nepal
dc.subjectpeer-reviewed journal article
dc.subjectopen access
dc.subjectDepartment of Civil Engineering
dc.titleStructural performance optimization of Reinforced concrete buildings with rooftop Telecommunication towers: A location-based analysis