Tribhuvan University, Institute of Engineering, Thapathali Campus
UGC Nepal accreditation badge
Accredited by UGC NepalUniversity Grants CommissionQuality Education Since 1967 A.D.

Structural performance optimization of Reinforced concrete buildings with rooftop Telecommunication towers: A location-based analysis

Abstract

This study evaluates the structural response of an RCC building in Parbat, Nepal, with a rooftop telecommunication tower positioned at various locations. In our case, a telecommunication tower is already located at a certain position in the building, and we are trying to evaluate the optimal position of telecommunication tower. The site lies in seismic Zone V as per IS 1893:2016 (Part 1), indicating very high seismic activity, and is subject to significant wind loads. This study examines the structural response of an RCC building with a rooftop telecommunication tower, using ETABS 18.1.1 and adhering to IS 1893:2016 (Part 1) seismic design standards. The analysis focuses on the impact of tower placement on critical structuralparameters, such as base shear, nodal displacement, axial and shear forces, and bending and torsional moments. Through five tower placement scenarios, the study highlights significant findings: a 2.37% increase in base shear, up to 9.86% variation in axial forces, and a maximum 26.60% change in shear forces. By isolating tower location as a variable, this research provides detailed insights into how tower positioning affects building performance. A finite element analysis approach is used, ensuring accuracy by explicitly modeling RCC-steel tower interactions and bolted connection of telecommunication tower and RCC structure.

Description

Journal: Journal of Innovations in Engineering Education (JIEE), ISSN 2594-343X (print), 2773-823X (online) Volume/Issue: Vol. 7, Issue 1 (2024), pages 131-137 Article type: Research Article Published: 2024-12-30 DOI: https://doi.org/10.3126/jiee.v7i1.72513 Authors and affiliations: - Bimal Ojha (Department of Civil Engineering, Institute of Engineering, Thapathali Campus) - Sabin Khatri (Department of Civil Engineering, Institute of Engineering, Thapathali Campus) - Prabin Pokharel (Department of Civil Engineering, Institute of Engineering, Thapathali Campus) - Rasique Jirel (Department of Civil Engineering, Institute of Engineering, Thapathali Campus) - Binay Jamarkattel (Department of Civil Engineering, Institute of Engineering, Thapathali Campus) - Abhinesh Khatri (Department of Civil Engineering, Kantipur Engineering College) TCIOE department(s): Department of Civil Engineering Publisher: Thapathali Campus, Institute of Engineering, Tribhuvan University License: Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0), https://creativecommons.org/licenses/by-nc-nd/4.0/ Journal website: https://journal.tcioe.edu.np/articles/aa0efe81-c70f-4b53-a1ee-a37d867684bd NepJOL: https://www.nepjol.info/index.php/jiee/article/view/72513

Citation

Ojha, B., Khatri, S., Pokharel, P., Jirel, R., Jamarkattel, B., & Khatri, A. (2024). Structural performance optimization of Reinforced concrete buildings with rooftop Telecommunication towers: A location-based analysis. Journal of Innovations in Engineering Education, 7(1), 131-137. https://doi.org/10.3126/jiee.v7i1.72513

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license