Structural performance optimization of Reinforced concrete buildings with rooftop Telecommunication towers: A location-based analysis
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Thapathali Campus, Institute of Engineering, Tribhuvan University
DOI
10.3126/jiee.v7i1.72513
Abstract
This study evaluates the structural response of an RCC building in Parbat, Nepal, with a rooftop telecommunication tower positioned at various locations. In our case, a telecommunication tower is already located at a certain position in the building, and we are trying to evaluate the optimal position of telecommunication tower. The site lies in seismic Zone V as per IS 1893:2016 (Part 1), indicating very high seismic activity, and is subject to significant wind loads. This study examines the structural response of an RCC building with a rooftop telecommunication tower, using ETABS 18.1.1 and adhering to IS 1893:2016 (Part 1) seismic design standards. The analysis focuses on the impact of tower placement on critical structuralparameters, such as base shear, nodal displacement, axial and shear forces, and bending and torsional moments. Through five tower placement scenarios, the study highlights significant findings: a 2.37% increase in base shear, up to 9.86% variation in axial forces, and a maximum 26.60% change in shear forces. By isolating tower location as a variable, this research provides detailed insights into how tower positioning affects building performance. A finite element analysis approach is used, ensuring accuracy by explicitly modeling RCC-steel tower interactions and bolted connection of telecommunication tower and RCC structure.
Description
Journal: Journal of Innovations in Engineering Education (JIEE), ISSN 2594-343X (print), 2773-823X (online)
Volume/Issue: Vol. 7, Issue 1 (2024), pages 131-137
Article type: Research Article
Published: 2024-12-30
DOI: https://doi.org/10.3126/jiee.v7i1.72513
Authors and affiliations:
- Bimal Ojha (Department of Civil Engineering, Institute of Engineering, Thapathali Campus)
- Sabin Khatri (Department of Civil Engineering, Institute of Engineering, Thapathali Campus)
- Prabin Pokharel (Department of Civil Engineering, Institute of Engineering, Thapathali Campus)
- Rasique Jirel (Department of Civil Engineering, Institute of Engineering, Thapathali Campus)
- Binay Jamarkattel (Department of Civil Engineering, Institute of Engineering, Thapathali Campus)
- Abhinesh Khatri (Department of Civil Engineering, Kantipur Engineering College)
TCIOE department(s): Department of Civil Engineering
Publisher: Thapathali Campus, Institute of Engineering, Tribhuvan University
License: Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0), https://creativecommons.org/licenses/by-nc-nd/4.0/
Journal website: https://journal.tcioe.edu.np/articles/aa0efe81-c70f-4b53-a1ee-a37d867684bd
NepJOL: https://www.nepjol.info/index.php/jiee/article/view/72513
Keywords
Telecommunicationtowerplacement Structural optimization , ETABS , Finite Element Analysis , Seismic performance , RCC building response , Tower-Structure interaction , JIEE , Journal of Innovations in Engineering Education , JIEE 2024 , JIEE Volume 7 , Research Article , Thapathali Campus , TCIOE , Institute of Engineering , IOE , Tribhuvan University , Nepal , engineering research Nepal , peer-reviewed journal article , open access , Department of Civil Engineering
Citation
Ojha, B., Khatri, S., Pokharel, P., Jirel, R., Jamarkattel, B., & Khatri, A. (2024). Structural performance optimization of Reinforced concrete buildings with rooftop Telecommunication towers: A location-based analysis. Journal of Innovations in Engineering Education, 7(1), 131-137. https://doi.org/10.3126/jiee.v7i1.72513
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwise noted, this item's license is described as Copyright (c) 2024 JIEE and the authors. Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0).


